npx skills add ...
npx skills add signoz/agent-skills --skill signoz-managing-views
npx skills add signoz/agent-skills --skill signoz-managing-views
Use when the user wants to create, list, get, update, rename, or delete a SigNoz saved Explorer view. Trigger on phrases like "save this query as a view", "save this filter", "bookmark this search", "list my saved views", "show me views for traces/logs/metrics/meter", "rename the X view", "update my saved view to also filter Y", "delete the X view", or any request to manage Explorer saved views — even if they don't say "view" explicitly. Also use when someone wants to share a recurring Explorer query with their team and asks how to "save" or "bookmark" it.
Create, read, update, and delete SigNoz saved Explorer views via the
SigNoz MCP server. A saved view is a reusable snapshot of an Explorer query
on the Logs, Traces, Metrics, or Cost Meter page — name + filters + panel
type, scoped to one sourcePage. They are not dashboards and not alerts.
This skill covers the full CRUD surface in one place because the operations share the same schema, the same identity model (UUID per view), and the same prerequisite resources. The only operation with real blast radius is delete, and update has a sharp edge (full-body replace) — both get explicit guards below.
This skill calls SigNoz MCP server tools (signoz_create_view,
signoz_list_views, signoz_get_view,
signoz_update_view, signoz_delete_view,
signoz_get_field_keys, signoz_get_field_values). Before
running the workflow, confirm the signoz_* tools are available. If
they are not, run signoz-mcp-setup first to initialize or repair the MCP
connection. Do not fall back to raw HTTP calls or fabricate view payloads
without the MCP tools.
Use this skill when the user wants to:
sourcePage, name, or category).Do NOT use when the user wants to:
signoz-creating-dashboards /
signoz-modifying-dashboards.signoz-generating-queries.signoz-creating-alerts.Read both resources BEFORE composing any create or update payload. Do not
hand-compose a compositeQuery from memory — the correct schema is not the
legacy builder.queryData format; it is the v5 spec described in these
resources. Sending a legacy payload causes a silent HTTP 400.
Read both MCP resources by URI using your client's resource-read mechanism:
signoz://view/instructions — SavedView field reference, sourcePage
rules, the GET-then-PUT update flow, the minimal create body.signoz://view/examples — round-tripped payloads (traces list, logs list,
metrics graph, and a Cost Meter graph) you can adapt verbatim.The server returns HTTP 400 on legacy v3/v4 fields (builder, promql,
unit, top-level id, queryFormulas, queryTraceOperator) — the failure
mode is silent for the user, so reading the resources first is mandatory, not
optional.
Resolve sourcePage — must be exactly one of traces, logs,
metrics, meter. If the user's intent is ambiguous ("save this query"),
ask which Explorer they mean. It cannot be inferred from filter strings
alone. Use meter for Cost Meter (usage / billing) views — it is a
distinct Explorer page from metrics, even though the query runs on the
metrics signal (see Step 4).
Read the schema resources. Read both signoz://view/instructions
and signoz://view/examples using your client's resource-read mechanism
before composing any payload. Do not skip this step even if you think
you know the schema — the legacy builder.queryData format is rejected
with HTTP 400.
Build the query using signoz-generating-queries — mandatory. Use
the Skill tool to invoke signoz-generating-queries. The sub-skill
handles field discovery, type checking, and live-data validation in one
pass — adapting an example payload from signoz://view/examples or
running a bare signoz_search_traces call skips the field-type
checks and service-name resolution that catch silent 400s before they
become permanent bad views. Skipping it means a malformed filter becomes
a saved view that must be deleted and recreated.
For a meter view, tell signoz-generating-queries it's a Cost Meter
query (source=meter) so discovery hits the meter store, not the default one.
Retain the exact query argument from its successful
signoz_execute_builder_query validation call, then translate it explicitly:
Build the top-level compositeQuery argument to signoz_create_view as
{ "queryType": "builder", "panelType": "<list|graph|table|value>", "queries": <copied queries> }. Copy the
queries array losslessly, but do not copy the execution-only envelope fields
schemaVersion, start, end, requestType, formatOptions, or
variables; do not put a query key or a second nested compositeQuery
inside the saved object.
Choose panelType from the saved-view intent rather than inventing it from
the execution envelope.
The copied queries must retain every positive spec.limit and v5
spec.order entry losslessly. Never translate them to dashboard orderBy.
Raw/list views use 100 rows (logs: timestamp/id desc; traces: timestamp
desc); standalone aggregate views and formula results use 100 groups.
Builder queries referenced by a formula use 10000 because their limits are
applied before evaluation. Order by the primary aggregation or __result
desc as appropriate. Time-series top-N ranks groups over the whole selected
window and can omit a short-lived local spike.
Enforce the signal rule in every builder_query spec.
traces / logs / metrics: signal == sourcePage. A
sourcePage:"traces" view with signal:"logs" is a server-side error.meter (Cost Meter): signal:"metrics" and source:"meter" —
a Cost Meter view is queried on the metrics signal against the meter
store. Omitting source:"meter" silently queries the default metrics
store; setting source:"meter" on a non-meter sourcePage is rejected.Mandatory pre-save sample fetch. Probe with the exact filter
from compositeQuery.queries[0].spec against the destination
signal:
sourcePage=traces → signoz_search_traces with limit=1sourcePage=logs → signoz_search_logs with limit=1sourcePage=metrics → signoz_query_metrics with the
metricName from spec.aggregations[0].metricName plus the same
filter, timeRange=1h, requestType=scalar. Repeat per metric
query if the view has multiple. The tool requires metricName —
a filter-only probe is not supported.sourcePage=meter → signoz_query_metrics with the metricName
from spec.aggregations[0].metricName, source=meter, the same
filter, timeRange=24h (Cost Meter rolls up hourly, so a 1h window
can be a single partial bucket), requestType=scalar.Required even if Step 3 ran cleanly: the sub-skill validates the query it authored, not whatever you persist after edits or lifts. Empty → save anyway / revise / abort. Autonomous mode without authorization to persist empty views: abort and escalate.
Preview before writing — this step is not optional. Before calling
signoz_create_view, show the user a summary: name, sourcePage,
panelType, the full filter expression, and the Step 5 probe result
("sample fetch: N rows in last 1h" — for a meter view the probe window
is 24h, so report it as such). For a human in the loop, wait
for confirmation. For an autonomous agent, log the preview and proceed.
Call signoz_create_view. The server populates id,
createdAt/By, updatedAt/By — never send those.
signoz_list_views requires a sourcePage. If the user did not
specify one and is searching by name, call it once per page (traces,
logs, metrics, meter) and merge — do not guess. Use the name and category
parameters for server-side partial-match filtering when the user gives a
substring; do not fetch everything and grep client-side.
The response paginates. Always check pagination.hasMore before
concluding a view does not exist. Default page size is 50; pass offset = pagination.nextOffset to continue. A view is only confirmed missing for a
given sourcePage once you have walked pages until hasMore = false. As
long as hasMore = true, keep paginating — there is no page-count cap.
Use signoz_get_view with the UUID. The returned data object is
the canonical SavedView shape — it is what you pass back to
signoz_update_view. Treat that data as the source of truth, not
whatever the user described from memory.
signoz_update_view is a full-body replace (HTTP PUT
upstream). Sending a partial body wipes the unspecified fields. The flow:
signoz_get_view with the view's id → returns
{ "status": "success", "data": { ...SavedView... } }.data object. Strip server-populated fields (id,
createdAt, createdBy, updatedAt, updatedBy) — the MCP server
strips them for you, but omitting them up front makes the diff
readable.compositeQuery (new filter, different panel
type, different aggregation), invoke signoz-generating-queries to
build and validate the new query before proceeding. Do not hand-edit
compositeQuery from the user's description — the same Step 4 signal
rule applies (including the meter case: signal:"metrics" +
source:"meter"), and panelType changes often imply a stepInterval
change too. For a meter view, tell signoz-generating-queries it is a
Cost Meter query (source=meter) so it discovers and validates against
the meter store. Derive the replacement saved compositeQuery from the
successful execution query using the same explicit translation as Create:
copy only query.compositeQuery.queries, then add queryType:"builder" and
the intended panelType. Exclude schemaVersion, start, end,
requestType, formatOptions, and variables. For pure metadata tweaks (rename,
recategorize), skip this step and do not touch compositeQuery.compositeQuery changed.
Run the 1-row probe from the Create flow's Step 5 against the new
filter. Empty → save anyway / revise / abort. Skip only for pure
metadata tweaks (rename, recategorize).name: "slow-checkout" → "slow-checkout-p99". Explicitly note
any fields that are unchanged (e.g. "compositeQuery: unchanged") and
include the Step 5 probe result when compositeQuery changed. This
prevents silent mistakes and gives the user a chance to catch a wrong
target view. Wait for confirmation on any change to compositeQuery,
since that changes what the view actually shows.signoz_update_view with { "id": "<id>", "view": <modified data> }.Deletion is destructive and immediately removes the view from the shared
list — any team member who had the view bookmarked will see it disappear.
Depending on the host application, the user may be offered a one-click
restore action shortly after the delete (the SigNoz Assistant captures a
snapshot and exposes a restore action), but treat that as a recovery
affordance, not a substitute for getting the delete right. Treat this like
dropping a row from a shared table:
signoz_list_views to find the view
by name. If sourcePage is unknown, search all four pages (traces,
logs, metrics, meter).signoz_get_view with the
UUID from step 1. Do NOT skip this step even when you got the UUID from
a list result that looks correct. List results are paginated and a name
match is not a UUID guarantee — signoz_get_view is the confirmation
that the UUID maps to the view the user named.
Never call signoz_delete_view on a UUID without a prior
signoz_get_view confirming the matching name and sourcePage.sourcePage, and
category, and explicitly ask for confirmation. Do not auto-confirm
based on the original prompt, even an emphatic one — destructive
operations get a fresh confirmation against the resolved target.signoz_delete_view. Report success with the deleted
view's name (not just the UUID), so the user can recognize it.For autonomous agents without a human in the loop: refuse delete unless the calling context has been explicitly authorized for destructive operations on saved views, and log the resolved view metadata before the call.
Mandatory pre-save sample fetch on create and on compositeQuery
updates. Step 5 of each flow runs a 1-row probe against the
destination signal using the exact filter from the about-to-save
payload. Skipping is equivalent to skipping get-before-delete. The
Step 3 signoz-generating-queries delegation is necessary but not
sufficient — it validates the query it authored, not the filter
you persist after edits.
Cross-signal-lift footgun: field keys are signal-scoped. An
attribute observed on metrics (e.g. oauth.error_code on a
counter) may not exist on traces or logs for the same
tenant, even when emitted by the same service. Lifting an attribute
from a sibling dashboard panel, alert rule, or view that targets a
different signal is the most common source of empty saved views.
signoz_get_field_keys signal=<destination signal> is necessary but
not sufficient — sparse emission still produces zero-result views.
Only the sample fetch confirms. The destination signal equals sourcePage
for traces/logs/metrics; for a meter view it is signal=metrics with
source=meter (never signal=meter).
A saved view returning zero rows under its own filter is a permanent artifact in a shared workspace; the human preview can't tell from JSON that the filter won't match, and autonomous mode has no preview, so the sample fetch is the only safety net.
Translate the execution envelope before saving. The executable query and
saved-view query intentionally have different outer shapes. Save exactly
{queryType, panelType, queries} in the create compositeQuery argument or
update view.compositeQuery, where queries
comes from the validated execution query.compositeQuery.queries. Never copy
the range, request, formatting, or variables envelope into a view.
| Operation | Tools called | Key guard |
|---|---|---|
| Create | read signoz://view/instructions + signoz://view/examples → signoz-generating-queries → sample fetch on exact filter → preview → signoz_create_view | Mandatory pre-save sample fetch; preview before write; no legacy fields |
| List | signoz_list_views (× 4 if no sourcePage given: traces/logs/metrics/meter) | Check pagination.hasMore |
| Get | signoz_get_view(id) | Returns canonical body for update |
| Update | signoz_get_view → modify → sample fetch if compositeQuery changed → diff preview → signoz_update_view | Full-body replace; sample fetch when compositeQuery changes; diff preview required |
| Delete | signoz_list_views → signoz_get_view → confirm → signoz_delete_view | Get-before-delete mandatory; fresh confirmation |
| Mistake | Fix |
|---|---|
Hand-composing compositeQuery from examples or memory (even after reading signoz://view/examples) | Use the Skill tool to invoke signoz-generating-queries — reading examples and validating with signoz_search_traces is not a substitute |
Copying the full executable query envelope into the saved compositeQuery | Copy only query.compositeQuery.queries, then construct the saved shape {queryType:"builder", panelType, queries}; exclude schemaVersion, start, end, requestType, formatOptions, and variables |
Lifting an attribute name from a metric, alert rule, or sibling view and using it in a sourcePage=traces / =logs view filter without re-verifying on the destination signal | Field keys are signal-scoped; an attribute on metrics may not exist on traces or logs. Always re-check via signoz_get_field_keys signal=<destination signal> (for a meter view, signal=metrics source=meter — never signal=meter) and run the mandatory pre-save sample fetch — the key check is necessary but not sufficient |
Skipping the pre-save sample fetch because signoz-generating-queries already validated the query | The sub-skill validates the query it authored; the filter you persist may have been edited or lifted since then. The Step 5 sample fetch is mandatory regardless |
Skipping signoz_get_view before delete (relying on list UUID alone) | Always call signoz_get_view to confirm name+sourcePage before signoz_delete_view |
Sending legacy fields: builder, promql, unit, top-level id, queryFormulas | Read schema resources; server returns HTTP 400 silently |
signal ≠ sourcePage in builder query | For traces/logs/metrics, every builder_query.signal must equal the view's sourcePage. For a meter view, use signal:"metrics" + source:"meter" (not signal:"meter") |
Filing a Cost Meter view under sourcePage:"metrics" (with source:"meter") | Cost Meter views go under sourcePage:"meter" — otherwise they're invisible in the Meter Explorer and mis-filed under Metrics. The server rejects source:"meter" on a non-meter page |
| Partial update body (omitting unchanged fields) | GET full body first → modify only changed fields → PUT entire body |
| Declaring "no such view" after only page 1 | Check pagination.hasMore; continue with offset = pagination.nextOffset |
| Using PromQL or raw ClickHouse in a view | Only queryType: "builder" is supported; offer a dashboard panel instead |
Setting category to an enum value | category is free-form string; omit if user doesn't specify |
After any write (create / update / delete), include in your reply:
sourcePage.sourcePage.After a view operation, you may surface up to 3 follow-up intents that match what just happened. The host application renders them — follow the host's UI rendering rules for the exact mechanism. Use your judgment about what's natural for the user's context; do not pad to 3.
Two anti-rules that override your judgment:
When the user is purely exploring ("just listing my views", "what's in here?") and signals no further intent, skip follow-ups entirely. No chips beat wrong chips.
Describe follow-ups by user intent, not by tool or skill name. The label the user clicks should read like the user's next prompt.
Read-only operations (list, get) should report concisely — name, id, sourcePage, filter expression, panel type — and stop. Don't narrate the schema back to the user.